The 35kV Bolted-type Tee Connector adopts the patented technology of WOER, which is suitable for the interface E bushing in the European EN50180&50181 standard, and also meets the Figure 15-Interface 13 bushing in the American IEEE 386-2016.
It is suitable for the (cross-linked power cable) inlet and outlet terminals of the ring network switch cabinet, and is also suitable for box-type substation devices. Provides a fully insulated and fully sealed connection from the power cable to the switch cabinet or cable branch box.
Ordering instruction
The ordering formula as followed:
| 1 | 2 | 3 | 4 | |
| WEB |
Step 1
Choose the system voltage and current: 35/630
Step 2
Select the range from Table D that fits the diameter over cable insulation
Step 3
Select the conductor code from Table C for the conductor size and type
Step 4
Select the package. 1: 1pc/kit; 3: 3pcs/kit.
Table D
Diameter over cable insulation
| Insulation Range Code | Diameter over cable insulation φ(mm) | |
| Min. | Max. | |
| A | 30 | 32 |
| B | 32 | 35 |
| C | 35 | 38 |
| D | 38 | 40 |
| E | 40 | 42 |
| F | 42 | 45 |
| G | 45 | 48 |
| H | 48 | 51 |
Table C
Conductor Code
| Conductor Cross-section (mm2) | Lug Code | |||
| Copper Lug (Hexagonal compression) | Aluminum Lug (Mechanical Bolted) | |||
| 50 | 03C | M1(AULZ25-95-16) | - | - |
| 70 | 04C | M2(AULZ70-240-16) | - | |
| 95 | 05C | - | ||
| 120 | 06C | - | - | |
| 150 | 07C | - | - | |
| 185 | 08C | - | M3(AULZ185-400-16) | |
| 240 | 09C | - | ||
| 300 | 10C | - | - | |
| 400 | 11C | - | - | |
| 500 | 12C | - | - | |
Ordering example:
The cable is 35kV, 3-core 95mm² copper conductor with core insulation diameter of 34mm. Order WEB 35/630B05C3.
Note:
Sealing or solderless grounding kits shall be ordered separately.
Insulated plug with capacitive test point is available upon request.
Please add "-X" for cable with copper wire shield without armour, like WEB 35/630B05C3-X.
Feel free to contact us for detailed information.
Technical Data
| Voltage Class | 42kV | |||
| Continuous Current | 630A | 1250A* | ||
| AC Withstand Voltage | 117kV for 5 min | |||
| Partial Discharge | 45kV, ≤10pc | |||
| Impulse Withstand Voltage (10 times for each polarity) | 200kV | |||
| Screen Resistance | ≤5000Ω | |||
Note: * refer to the condition when installed on an appropriate equipment bushing.
High-quality EPDM rubber is used, which not only has excellent electrical properties, but also has tear resistance, ozone resistance, oxidation resistance, corrosion resistance, and high mechanical strength.
The internationally advanced three-layer injection process effectively guarantees the interface performance, avoids interlayer gaps, and minimizes local discharge.
The internal and external shielding design of the shielded connector makes the electric field structure more optimized; the uniform outer shielding layer, the grounding resistance is less than 5000Ω, ensuring the personal safety of maintenance operators.
The adopter a patented anti-slip design, which can effectively prevent accidents caused by the misalignment of the adopter body during installation.
It has good thermal stability and thermodynamic properties.